Installation guide

Installation guide: BT 0 kit 1

For direct ceiling mounting. Item no. 352001 / 362001 (Low Noise).

  • BALL-TIK 0 series, track profile 36 x 36 mm
  • Max. load 200 kg per gate leaf
  • Max. 1800 mm door width
  1. Position and fasten the rail.
    01Position and fasten the rail.
  2. Adjust the roller and prepare the carriage.
    02Adjust the roller and prepare the carriage.
  3. Insert the carriage into the rail.
    03Insert the carriage into the rail.
  4. Fit the end stop with PVC buffer.
    04Fit the end stop with PVC buffer.
  5. Position the door mounting brackets.
    05Position the door mounting brackets.
  6. Fix the brackets to the door.
    06Fix the brackets to the door. (4x)
  7. Adjust and secure.
    07Adjust and secure.
  8. Check operation.
    08Check operation.

Good to know

  • The rail is not included in the kit and must be ordered separately.
  • Kit contents: 2 pcs gate roller, 2 pcs carrier plate and 2 pcs track stop.
  • We recommend a maximum of 700 mm between the brackets.
  • Do not use oil as a lubricant on the wheels. It dries out the bearings.

Need help?

A/S Tobias Jensen Production, phone +45 43 27 16 85, email ordre@ball-tik.com.